Removing Chimney Breast Ground Floor Flat
However if your chimney extends below the floor and into the foundation you re looking at fixing floor framing and potentially some foundation work.
Removing chimney breast ground floor flat. I don t know all the ins and outs of the regulations but there definitely should be a supporting beam which could have been put into the ceiling so not visible depending on the structure of the house and there should have been building regs approval for the work so the council. One of the most common internal alterations carried out is to remove an obsolete chimney breast at ground floor to create more floor space. An internal chimney breast can be removed at ground and or first floor without having to remove the external stack. However chimney removal costs vary from one chimney to the next for a number of.
No only does this mean it is actually not as disruptive as you might have thought but it also avoids the need to alter the roof or external appearance and character of the building. I m about to get a chimney breast removed from one room but not the room above so i ve had to get advice recently. When people think of a chimney this is the part they tend to picture. One of the most important aspects of a chimney breast removal project is making sure the structure of the home is still intact after the chimney breast has been taken out.
If you are removing it completely the roof will also need to be patched up. Yes this is regularly done for clients is relatively straight forward. It is the portion which protrudes from the roof ending in a cap. Cost to have chimney removed removing an entire chimney stack and breast costs 2 000 4 000 on average.
I am looking to remove a load bearing wall and the chimney breast attached to it which is located in the centre of the house so. Once a chimney breast has been removed you will need to make good the floor where the chimney breast once was. We would need to explore the flooring above the chimney to expose the joist giving access to calculate the dimensions of re enforced steel joist to sit within the ceiling floor void therefore removing the bulk head or inner beam visible within the ground floor space. Building regulations apply to this work because it is a material alteration to the structure ensuring the remaining.
Note that removing any portion of a chimney breast will require structural reinforcements for that floor and the one above as well as possible reinforcement of the outer wall.